AX = B10Ah subfn 1042h BH = bus number BL = device/function number (bits 7-3 device, bits 2-0 function) DI = register number (0000h-00FFh) (see #00878)
Return:
CF clear if successful ECX = dword read CF set on error AH = status (00h,87h) (see #00729) EAX, EBX, ECX, and EDX may be modified all other flags (except IF) may be modified
Notes: This function may require up to 1024 byte of stack; it will not enable interrupts if they were disabled before making the call. The meanings of BL and BH on entry were exchanged between the initial drafts of the specification and final implementation
See Also:
AX=B10Ah - AX=B10Ah/SF=1022h - AX=B10Ah/SF=1045h -
Format of PCI Configuration data for PC Technology RZ-1000 EIDE controller:
Offset Size Description (Table 00928)
00h 64 BYTEs header (see #00878)
(vendor ID 1042h, device ID 1000h)
10h DWORD base address for controller I/O registers
(set to 01F1h for primary controller, 0171h for secondary)
14h DWORD base address for controller digital I/O port
(set to 03F5h for primary, 0375h for secondary)
40h DWORD ???
bits 7-1: bit 13: bit 16: