Int 15/AX=53B0h/BH=10h

Prev Next Ralf Interrups Categories Contents

------

Intel System Management Bus - REQUEST

AX = 53B0h
BH = 10h
BL = protocol (see #00487)
CH = device address
CL = device command (see #00488)
DH = MSB Data or block length (for BlockWrite)
DL = LSB Data or first byte of block (for BlockWrite)

Return:
CF clear if successful AH = 00h or 80h (SMBus OK) (80h indicates a previously unreported SMI took place) CF set if error AH = error code (05h,10h,11h,12h,13h,14h,17h,19h,1Ah,86h) (see #00484)

Desc: Request access to a device on the SMBus

See Also: AX=53B0h/BH=11h - AX=53B0h/BH=13h

(Table 00487) Values for Intel System Management Bus protocol codes: 00h Quick Command 01h Send Byte 02h Receive Byte 03h Write Byte 04h Read Byte 05h Write Word 06h Read Word 07h Block Write 08h Block Read 09h Process Call 0Ah-FFh reserved

See Also: #00488

(Table 00488) Values for Intel System Management Bus Smart Battery command codes: Cmd Protocol(s) Description 00h Rd/Wr Word "ManufacturerAccess" implementation-specific 01h Rd/Wr Word get/set Low Capacity Alarm threshold 02h Rd/Wr Word get/set Remaining Time Alarm value (in minutes) 03h Rd/Wr Word get/set battery characteristics (see #00489) 04h Rd/Wr Word "AtRate" indicate charge/discharge rate 05h Read Word "AtRateTimeToFull" time to completely charge (in min.) 06h Read Word "AtRateTimeToEmpty" time to entirely discharge (min.)

07h Read Word "AtRateOK" boolean:
Can battery supply another 10sec? 08h Read Word internal battery temperature (in 0.1 Kelvins) 09h Read Word current battery voltage in millivolts 0Ah Read Word current flowing through battery in milliamperes (positive if charging, negative if discharging) 0Bh Read Word average current over the past minute 0Ch Read Word expected error margin in capacity computations in % 0Dh Read Word predicted remaining charge as % of full charge 0Eh Read Word predicted remaining charge as % of design capacity 0Fh Read Word predicted remaining charge in mAh or 10mWh 10h Read Word predicted full charge capacity in mAh or 10mWh 11h Read Word predicted remaining battery life in minutes FFFFh = not discharging 12h Read Word rolling average of predicted life over past minute 13h Read Word rolling average of predicted charge time over past min. FFFFh = not charging 14h Read Word get battery's desired charging current in mA 14h Write Word set charging current in mA 15h Read Word get battery's desired charging current in mV 15h Write Word set desired charging voltage in mV 16h Read Word get current battery status (see #00490) 17h Read Word get number of charge/discharge cycles for battery 18h Read Word get design capacity in mAh or 10mWh 19h Read Word get design voltage 1Ah Read Word get specification information (see #00491) 1Bh Read Word get manufacture date (see #01665 at INT 21/AX=5700h) 1Ch Read Word get serial number 1Dh-1Fh reserved 20h Read Block get manufacturer's name 21h Read Block get device name 22h Read Block get device chemistry (see #00492) 23h Read Block get manufacturer data 24h-2Eh reserved 2Fh manufacturer-specific 30h-3Bh reserved 3Ch-3Fh manufacturer-specific

Note: Bits 7-6 are reserved for addressing multiple batteries in a future version of the specification

See Also: #00487

Bitfields for Smart Battery battery characteristics: Bit(s) Description (Table 00489) 0 battery has internal charge controller (read-only) 1 primary/secondary battery support (read-only) 6-2 reserved 7 conditioning cycle requested 8 internal charge controller enabled 9 battery operating in primary mode 13-10 reserved 14 disable broadcast to charger 15 report capacity in units of 10mW / 10mWh instead of mA / mAh

See Also: #00488 - #00490

Bitfields for Smart Battery battery status: Bit(s) Description (Table 00490) 15 overcharged 14 terminate-charge alarm 13 reserved 12 over-temperature alarm 11 terminate-discharge alarm 10 reserved 9 remaining-capacity alarm 8 remaining-time alarm 7 initialized 6 charging 5 fully charged 4 fully discharged 3-0 error codes. 0000 OK. 0001 busy. 0010 reserved command. 0011 unsupported command. 0100 access denied (tried to write to read-only value). 0101 overflow/underflow. 0110 bad size. 0111 unknown error

See Also: #00488 - #00489 - #00491

Bitfields for Smart Battery specification information: Bit(s) Description (Table 00491) 3-0 SmartBattery specification minor revision number 7-4 SmartBattery specification version number 11-8 voltage scaling (0-3, multiply voltages by 10^scale) 15-12 current scaling (0-3, multiply currents by 10^scale)

See Also: #00488 - #00490

(Table 00492) Values for Smart Battery device chemistry (not case-sensitive): "LION" Lithium ion "NiMH" Nickel metal hydride "PbAc" lead-acid "NiCd" Nickel Cadmium "NiZn" Nickel Zinc "RAM" rechargeable Alkaline Manganese "ZnAr" Zinc-Air

See Also: #00488

Category: Expansion Bus Bios - Int 15h - I

------