Interrups | Categories | Contents |
AX = 2716h
Return:
AX = 0000h if AX=2716h,AX=2717h,AX=2718h supported CX = bytes in paste buffer DX = current generation number (updated after every copy operation)
BUG: Novell DOS 7 TASKMGR returns AX=0000h even though it does not support this call (it does support the remainder of the TaskMAX API)
See Also: AX=2701h - AX=2713h - AX=2714h - AX=2717h -
Category: DOS-Based Task Switchers/Multitaskers - Int 2Fh - D
Interrups | Categories | Contents |
|